Temperature Data Change

The Euromap77 trigger initiates data transfer when the temperature value of a data point changes. The following trigger applications are available:

  • Temperature Data Change: Monitors temperature changes within the selected injection molding machine.
  • Temperature Deviation: Monitors temperature threshold violations of the selected injection molding machine.

The individual properties are:

PropertyDescription
ProfileThe profiles are available here as configured instances of the Euromap77 plug-in. Select a profile from the drop-down list.
End pointSelect an end point from the drop-down list. Use the "Test" button to check whether your connection is working.
MachineSelect a machine from the drop-down list. The list below now shows a selection list with all possible information about this machine. Activate the areas that are necessary for your project planning. You can now use this selected information as transfer information.

By selecting the temperature zone type "Injection unit" or "Mold" and the corresponding temperature monitoring option, you can define the other properties:

Properties Temperature Datachange Trigger

PropertyDescription
No more thanTime interval in which data is always transferred, even if the value of the data point has not changed. Default is always a whole number, no decimal places. Therefore, milliseconds, seconds, minutes, or hours must be selected as units.
At least every

If the value of the data point changes frequently, the transfer rate can be limited here via an interval. The entry therefore means: "Transmission will take place at most every second, for example, even if the value changes more frequently."

The default is always a whole number, no decimal places. Therefore, milliseconds, seconds, minutes, or hours must be selected as units.

Trigger at ... % differenceThe transfer is only triggered if the value of the data point changes by this entry (relative).
Trigger at ... absolute differenceThe transfer is only triggered if the value of the data point changes by this entry (absolute).
Trigger at every data changeDefault setting, overrides Trigger at ... difference.

Properties Temperature Datachange Trigger

PropertyDescription
Trigger when falling below LowDeviationTemperature1When activated, triggering only occurs when the temperature falls below the low deviation temperature.
Trigger when exceeding HighDeviationTemperature1When activated, triggering only occurs when the temperature exceeds the highest deviation temperature.